Fork me on GitHub

xray.Timer(1) Manual Page

Name

xray.Timer - Time calculation of the X-ray target.

Synopsis

xray.Timer [-AAgghSSUUvvV] [--nsf] [--nsf] [--rmo] [--rmo] [--aRadBuffer=0.75] [--aRadBuffer=0.75] [-B=1.0] [-B=1.0] [--FSigFCutoff=-1.0] [--FSigFCutoff=-1.0] [-G=0.6] [-G=0.6] [-m=coordinates] [-m=coordinates] [-n=5] [-n=5] [--nBins=10] [--nBins=10] [--nResidueBFactor=0] [--nResidueBFactor=0] [--nt=0] [--nt=0] [-R=-1] [-R=-1] [--sigmaATol=0.05] [--sigmaATol=0.05] [--sol=POLYNOMIAL] [--sol=POLYNOMIAL] [--wA=1.0] [--xrayScaleTol=1. _ 0e-4_] [--xrayScaleTol=1.0e-4] [-X=<data> <data> <data>]…​ [-X=<data> <data> <data>]…​ files…​

Description

Time calculation of the X-ray target.

Options

-h, --help

Print command help and exit.

-V, --version

Print the Force Field X version and exit.

--wA, --dataWeight=1.0

The weight of the experimental data (wA).

Timing Options

-g, --noGradient

Ignore computation of the atomic coordinates gradient.

-n, --iterations=5

Number of iterations.

--nt, --threads=0

Number of SMP threads (0 specifies use of all CPU cores).

-v, --verbose

Print the energy for each iteration.

X-ray Refinement Options

-m, --mode=coordinates

Refinement mode: coordinates, bfactors and/or occupancies.

--rmo, --refineMolOcc

Refine molecular occupancy.

X-ray Reflection Data Options

--FSigFCutoff=-1.0

F / SigF cutoff (-1.0 is no cutoff).

--nBins=10

The number of refection bins.

-R, --rFreeFlag=-1

R-Free Flag value (-1 attempts to auto-determine from the data).

-X, --data=<data> <data> <data>

Specify input data filename, its weight (wA) and if its from a neutron experiment (e.g. -X filename 1.0 false).

X-ray B-Factor Options

-B, --bSimWeight=1.0

B-Factor similarity weight.

--nResidueBFactor=0

Number of residues per B-factor. 0 uses atomic B-factors (default).

-U, --addAnisoU

Add Anisotropic B-Factors to refinement.

X-ray Target Options

-A, --allGaussians

Use all defined Gaussians for atomic scattering density (the default is to use the top 3).

--aRadBuffer=0.75

Scattering is evaluated within the atomic radius plus this buffer (Å).

-G, --sampling=0.6

The number of grid spaces per Angstrom for the scattering FFT grid.

--nsf, --noSplineFit

Use a resolution dependent spline scale factor.

--sigmaATol=0.05

Sigma A optimization tolerance.

--xrayScaleTol=1.0e-4

X-ray scale optimization tolerance.

X-ray Bulk Solvent Options

-S, --solventGridSearch

Perform a grid search for optimal bulk solvent parameters.

--sol, --solvent=POLYNOMIAL

Bulk solvent scattering model [Polynomial/Gaussian/Binary/None]

Arguments

files…​

PDB and Diffraction input files.